Current location:Home >Products>Pulse Vacuurn Steana Sterilizer

Vertical Pulse Vacuurn Steana Sterilizer

Part parameters

Packaging Details:
Delivery Time:
Description:

Detailed introduction:

Pulse vacuum automatic

Use

The vertical pressure steam sterilizers are assembled with heating system, micro-computer controlled system, over heat and over pressure protection system, which are reliable for the Sterilizing effects, convenient of operation and energy conservation. They are ideal equipments for clinics, scientific research institutes and other organizations to sterilizer surgical instruments, fabrics, glasses, culture media etc.

 

Characteristics

• Microcomputer controlled. digital display of working statues, touch type key.
•It dynamically shows the temperature. pressure time .vacuum rate and the cycle status
• With fully automatically route of the water inlet. pulse vacuum. heating. sterilizing, draining. exhausting and vacuum drying
• 3 times pulse vacuum the vacuum rate would reach -0.081mpa after that. which ensure the completely extracting of inner air from the dressing and A,B type hollowed appliance
• With 4fixed programs for the appliance,medical dressing, rubber and fluid, the user also could set the program as they need randomly
• Equipped with the PY/TT testing connector, easy for running the testing
• Multiple pulse Vacuum drying after sterilizing. which ensure the good sterilizing rcsult
• Equipped with 0.22μm bacteria filter. it ensure the air which enter the inner vacuumed chamber is sterile. avoid the second time contamination.
• Hand wheel type for quick-open the door. Self-inflating type seal
• Adopted with immersed heating tube. with high heating efficiency.
• Steam-water inner circulation system: no steam discharge, and the environment for the sterilizing will be clean and dry
• Automatically shut off with beep reminding after sterilization.
• Fully high quality stainless, equipped with double stainless steel baskets

Technical Data


Technical Date LS-50HV LS-75HV LS-100HV
Chamber volume 50L
φ 340 x 550mm
75L
φ 400 x 600mm
100L
φ440x 650mm
Working Pressure 0.22Mpa
Working temperature 134℃
Max.Working Pressure 0.23Mpa
Heat average ≤ ±1 ℃
Timer range 0~99min
Temperature adjust range 0~134℃
Power

3000W/AC 220V ,50HZ

4500W/AC 220V,50HZ

4500W/AC 220V,50HZ

Overall dimension 690x470x1140 730x510x1270 750x550x1305
Transport dimension 760x550x1290 820x600x1380 840x640x1410
G.W/N.W 120Kg / 100Kg 140Kg / 118Kg 160Kg / 128Kg