CONTACT

Add: Room 2001、2002、2003、2011, Zhonghai International Plaza No. 237, Wannianquan Road, Qingdao, Shandong 266199 China

Tel: +86 532 8281 2277

Mobile : +86 186 5320 8877(WhatsApp)

Email: market@hiprove.cn   lena@hiprove.cn

PRODUTS

Current location:Home >Products>Pressure Steam Sterilizer

Horizontal Cylindrical Pressure Steam Sterilizer

Part parameters

Packaging Details:
Delivery Time:
Description: The horizontal autoclave, which adopte the way of gravity exchange to release the cold air the chamber more completely to ensure the reliable sterilization.

Detailed introduction:

 

Use

The horizontal autoclave, which adopte the way of gravity exchange to release the cold air from the chamber more completely to ensure the reliable sterilization. The control system automatically adjust the steam inlet and outlet according to chamber temperature during sterilizing This unit is an ideal equipment for clinics, scientific research institutes and other organizations to sterilize surgical instruments, fabric glassed, and the culture media etc.

Characteris tics

• Automatially controlled the slerilizing process, easy to operate.
•With drying function, suitable for the medical dressing drying
• With Over- temperature, over- pressure auto-protect
• The door can not be open until the pressure in the chamber is reduced to 0.027MPa. And the unit can not be started on if the door doesn't close well.
• The safety valve will be open automatically when the inner pressure over 0 .24MPa and the steam would be exhausted the water tank
• Automatically cut off the power if the water- Iack happened and alarm at the meanwhile.
• Fully stainless steel structure.

 

Technical Data


Technical Date WS-150YDC WS-200YDC WS-280YDC WS-400YDC
Chamber volume 150L
φ 440 x 1000mm
200L
φ 515 x 1000mm
280L
φ 600 x1000mm
400L
φ 700 x 1100mm
Working Pressure 0.22Mpa
Working temperature 134℃
Temperature adjust range 40~134℃
Time for sterilization 0~60min
Time for drying 0~60min
Heat average ≤ ±2 ℃
Power

9Kw/ 380V ,50HZ

9Kw/380V ,50HZ 12Kw/380V ,50HZ 18Kw/380V ,50HZ
Dimension 1400x600x1300 1400x670x1650 1400x770x1780 1430x880x1830
Exterior package dimension 1550x750x1850 1560x820x1850 1680x920x2100 1600x1050x2100
G.W/N.W 320 /240Kg 350 / 260Kg 465/365Kg 530/420Kg


Interested in this product, please leave us a message
Tel: +86 532 8281 2277   Mobile : +86 186 5320 8877(WhatsApp)   Email: market@hiprove.cn lena@hiprove.cn